The Norres Baggerman Group specifies the relevant pressure ratings for its hoses. However, there is no single ISO standard governing the applicable pressure ratings and test methods for every type of hose. Furthermore, many manufacturers do not state which test method was used or how the specified positive-pressure and vacuum ratings should be interpreted. This makes it difficult, and in some cases impossible, for users to compare catalogue data from different manufacturers directly.

This information page provides an overview of the different standardised test methods and the relevant pressure ratings for each type of hose.

The relevant standards are:

  1. DIN EN ISO 1402:2021-08
    Among other things, this standard specifies methods for the hydrostatic testing of rubber and plastics hoses and hose assemblies. These include determining the change in length at a specified test pressure and determining the burst pressure, i.e. the pressure at which the hose or hose assembly bursts.
  2. DIN 26057:2026-04
    This standard applies to spiral hoses made of thermoplastic polyurethane (TPU) with steel-wire reinforcement for granules and powdered materials. Among other things, it describes the procedure for testing positive-pressure and vacuum resistance.
  3. DIN EN ISO 7751:2017-06
    For rubber and plastics hoses and hose assemblies, this standard specifies the ratios of test pressure and minimum burst pressure to maximum working pressure.

Pressure ratings and hose types

Testing AIRDUC®and PROTAPE® hoses made of TPU

Norres Baggerman states positive-pressure and vacuum ratings in accordance with DIN 26057 in the data sheets for AIRDUC® and PROTAPE® hoses made of TPU. In some cases, additional pressure ratings are shown in brackets. These indicate the positive pressure under short-term loading at 25% or 50% elongation and vacuum values for axially fixed hose lengths approximately 1 m long that are close to collapse. Comparable information is also used by other manufacturers

Measuring pressure resistance in accordance with DIN EN ISO 1402 and DIN 26057:

  • Test equipment: The pressure source is a device capable of generating a fluid pressure of at least 6 bar. The test specimen is a length of hose with a free length of 1,000 mm between the hose connectors or fittings.
  • Conditioning: The test may be carried out no earlier than 24 hours after the hose length has been manufactured. Before testing begins, the specimens must be conditioned at room temperature for at least three hours.
  • Procedure: The specimens are clamped into the test apparatus. The hose ends are pushed onto the connectors and secured with suitable hose clamps without damaging the hose. The hose clamps must secure the specimen safely and tightly to the connectors. The free hose length between the connectors must be 1,000 mm. The specimen must be stretched and aligned as straight as possible in the test apparatus. The test temperature must correspond to room temperature. Pressure resistance is defined as the pressure maintained unchanged for one minute without the hose elongation exceeding 10%. The corresponding pressure-resistance values must be stated. Because of the maximum permitted elongation of 10%, it may not be possible to determine values for Type 1 hoses due to their design.
  • Test results: The test result is stated as the positive pressure in bar at a hose elongation of 10%. In some cases, we also show pressure ratings in brackets for short-term loading at 25% to 50% hose elongation, as some other manufacturers do. However, we advise against using the products under these conditions.

Measuring vacuum resistance in accordance with DIN 26057:

  • Test equipment: A vacuum pump using air as the test medium is used. With uniform evacuation, it must achieve an absolute pressure of 0.2 bar (−0.8 bar vacuum). The test specimen is a length of hose with a free length of 1,000 mm between the hose connectors.
  • Conditioning: The test may be carried out no earlier than 24 hours after the hose length has been manufactured. Before testing begins, the specimens must be conditioned at room temperature for at least three hours.
  • Procedure: The specimen is installed in the test apparatus. The hose is pushed onto the test connectors and secured with hose clamps without damaging it. The specimen must be stretched and aligned as straight as possible in the test apparatus. The outside diameter of the test connectors corresponds to the inside diameter of the specimen. The test connectors are designed so that the test medium cannot escape during the test. One test connector is rigidly connected to the test apparatus and cannot rotate. The other test connector is mounted so that it can rotate, allowing the specimen to twist during the test. The carriage moves freely, allowing the length of the specimen to change during the test.
    Vacuum resistance is defined as the pressure maintained unchanged for one minute without the hose shortening exceeding 10%. The corresponding vacuum-resistance values must be stated. Because of the maximum permitted shortening of 10%, it may not be possible to determine values for Type 1 hoses due to their design.
  • Test results: The test result is stated as the vacuum in bar at a hose shortening of 10%. In some cases, we also show in brackets vacuum values for straight, axially fixed hose lengths 1 m long that are close to collapse, as some other manufacturers do. However, we advise against using the products under these conditions. For some PROTAPE® hoses with wall thicknesses of 0.4 to 0.6 mm, the 10% hose shortening cannot be measured due to the design. In these cases, we state recommended operating limits.

Testing rubber hoses

Norres Baggerman tests rubber hoses on the basis of the requirements of DIN EN ISO 7751 and DIN EN ISO 1402:

ApplicationRatio of test pressure to maximum working pressureRatio of burst pressure to maximum working pressure
Hose for water, all other liquids, or suspended solids in liquids or air1.53.0
Hose for steam5.010.0

The working pressure can be found in the standard marking on the hose. For all other hose types, the stated pressure ratings are recommended operating limits at 20°C.

Do you have any questions about pressure ratings or the associated measurement methods?
The Norres Baggerman Group’s team of experts will be happy to assist you!

Subject to technical modifications.