Work safety notes

Work safety regarding working with a knife:

  • Always wear cut-resistant gloves
  • Arms must be held in parallel position. Do not cross arms while cutting.
  • Hold the hose a minimum safe distance of 10cm from the cutting tool

Technical hoses

Cutting of spirally reinforced plastic hoses

01.png
Step 1:

Cut through the hose material, preferably with a serrated knife.

02.png
Step 2:

Snip the supporting spiral with wire pliers.

Cutting of the metal hoses 375 - 377

03.png
Step 1:

Fix the ends with rivets or by soldering.

04.png
Step 2:

Lever out the profile with a screw driver.

05.png
Step 3:

Cutting of the protruding profile with a shear blade or diagonal cutting pliers.

Grounding for protection against electrostatic charging

Effective and permanent grounding of all installation components (including hoses and hose fittings) provides protection against disruption to media flow or ignition of explosive atmospheres. Please note our corresponding data sheet electrostatic charging.

13.png
Variant 1:

Expose the spiral, bend it to the inside and insert the conductive hose fitting.

14.png
Variant 2:

Expose the spiral and fix it, for example, by a rivet or screw.

Strip insulation of AIRDUC® hoses

15.png
Step 1:

Cut hose with a sharp knife along the steel wire.

16.png
Step 2:

Remove plastic from around the wire with a wire stripper...

17.png

...or remove it more convenient with a precision insulation stripper.

Pulling out the earthing wire of NORPLAST® PUR-C / PVC-C AS hoses

IMG_1062_toned_blue.png
Step 1:

Cut half of a circumfer-ence of the hose wall next to the grounding wire. The grounding wire stays on the residual part of the hose.

IMG_1062_toned_blue_scope.png
(Detail view)

The grounding wire is located centrally between the hard plastic coils in the hose wall.

IMG_1067_toned_blue.png
Step 2:

Then, cut-off the pro-truding hard-plastic spiral with a side-cutter.

IMG_1069_toned_blue.png
IMG_1073_toned_blue.png
Step 3:

Cut round ¼ of the hose wall next to the wire, leaving the wire in the detached part of the hose wall.

IMG_1073_toned_blue_scope.png
IMG_1082_toned_blue.png
Step 4:

Grip the detached strip of hose wall and pull until the grounding wire is exposed.

IMG_1086_toned_blue.png
IMG_1089_toned_blue.png
Step 5:

Separate the grounding wire and hose wall by carefully pulling them apart. Cut off the loose end of the hose wall with the side-cutter.

IMG_1092_toned_blue.png
IMG_1097_toned_blue.png

For grounding, bend the ground-ing wire into the hose and insert the conductive hose fitting to be earthed.

Notes on electrical grounding

  • The grounding wire should be electrically grounded on both ends of the hose.
  • After grounding, measure the electrical resistance between the two grounded hose ends. The electrical and surface resistance should measure <109 Ohm.
  • Please take into consideration any special regulations, local laws or provisions that are applicable to your situation or application.

Leak-proof assembly

A satisfactory seal can be assured when using our specially-developed spiral hose clamps. Leaking media can pose a threat to people and the environment, as well as causing process problems and reduced efficiency.

18.png

Leak-proof assembly using our original accessories.

19.png

Significant leakage resulting from use of conventional hose clamps.

Cable protection hoses

Cutting of bare or plastic coated cable protection hoses of metal (types 101 – 109)

By bending
CM_14_09_06.png
Step 1:

Cut the plastic mantle (if existing).

CM_14_09_07.png
Step 2:

Bend the metal hose.

CM_14_09_08.png
Step 3:

Cutting of the protruding profile with a shear blade or diagonal cutting pliers.

By intersecting
CM_14_09_06.png
Step 1:

Cut the plastic mantle (if existing).

CM_14_09_10.png
Step 2:

Bend the metal hose.

CM_14_09_11.png
Step 3:

Cutting of the protruding profile with a shear blade or diagonal cutting pliers.

By sawing
CM_14_09_12.png

Cut the metal hose on a belt saw at high cutting speed.

NORDUC® one hand assembly system

Due to the conic inside and the snap in hooks, the connector is universal suitable for different tube profiles. (Stand-ard-, Coarse- and UFW-profile) IP 65 is reached acc. to EN 60529/IEC 60529 in this combination. The IP 68 rate is attained with an O-ring sealing, mounted in the first wave trough of the tube (trade size 50 in the first and second groove).

CM_MA_NORDUC_01.png
Step 1:

Separate the tube at a cor-rugation crest (optimal protection of the tube and connector).

CM_MA_NORDUC_02.png
Step 2:

Insert the tube into the „closed“ connector as far as it will go (to assemble the connector).

CM_MA_NORDUC_03.png
Step 3:

Pull the corrugated tube back slightly inside the connector (to latch securely).

CM_MA_NORDUC_04.png
Step 4:

Move the detent lugs out (to dismantle the connector)

CM_MA_NORDUC_05.png
Step 5:

Pull the corrugated tube out of the connector.

CM_MA_NORDUC_06.png
Step 6:

Push the detent lugs in (NORDUC® assembly system ready to use again).