Temperature resistance at elevated temperatures
Technical specifications are generally based on measurements at 68 °F. At higher temperatures, the increasing softening of the material leads to a reduction in these values:
| Residual strength at a temperature of | Soft PVC | Pre-PUR® | Pre-PUR® HT |
|---|---|---|---|
68 °F / 20 °C | 100% | 100% | 100% |
86 °F / 30 °C | 70% | 90% | 95% |
104 °F / 40 °C | 50% | 80% | 90% |
122 °F / 50 °C | 30% | 70% | 85% |
140 °F / 60 °C | - | 50% | 75% |
158 °F / 70 °C | - | 30% | 60% |
212 °F / 100 °C | - | 20% | 40% |
257 °F / 125 °C | - | 10% | 20% |
302 °F / 150 °C | - | - | 10% |
These factors must be taken into account for applications involving positive pressure.
Example: Permissible operating limit for polyurethane at 104 °F (40 °C)::
pallow(108° F) = pallow(68 °F) × 80 %
Subject to technical modifications.