Electrostatic charging
General information
When solids and liquids are conveyed through pipes and hoses that can accumulate electrical charges, friction between the conveyed material and the hose wall as well as friction within the medium generates electrostatic charging (= charge separation). This can result in the following hazards and adverse effects in particular:
- Incendive discharges that can ignite explosive mixtures of gases, vapours, mists or dusts.
- Accident-prone behaviour caused by a startle reaction when a discharge passes through the human body.
- Process disruptions caused by the medium adhering to the hose wall.
- Interference with measuring and control equipment.
While measures addressing hazards 2 to 4 largely depend on the specific application, relevant regulations and technical rules apply to the assessment and prevention of ignition hazards caused by electrostatic charging.
An important protective measure is to prevent hazardous electrostatic charging by selecting suitable hoses and integrating them correctly into the overall system, or to dissipate such charges safely.
Our products have proven themselves in practice for the following reasons in particular:
- The hose can be grounded over its entire length.
- Fittings at both ends can be incorporated into the grounding or potential equalisation system.
- Unlike externally attached copper braids, the embedded wire provides a large contact area with the plastic.
- Unlike axially attached braids, the spiral construction covers the largest possible proportion of the hose surface.
- Depending on the application, hose types made from antistatic or dissipative plastics or electrically conductive plastics are available.
Regulations for preventing electrostatic ignition hazards
In Germany, TRGS 727 “Avoidance of ignition hazards due to electrostatic charging” is now particularly relevant to preventing ignition hazards caused by electrostatic charging. It specifies the requirements of the German Hazardous Substances Ordinance and includes requirements relating to the prevention of electrostatic ignition hazards, grounding and potential equalisation.
In addition, specific rules and information issued by the German Social Accident Insurance institutions exist or previously existed for certain industries and applications. Some of these older regulations have since been replaced or updated by more recent DGUV regulations or Technical Rules. Their fundamental safety-related statements may nevertheless remain relevant when assessing certain applications.
BGR 730 – Fire and explosion protection for systems used to extract and separate wood dust and chips
The former German Social Accident Insurance rule BGR 730 specified fire and explosion protection requirements for systems used to extract and separate wood dust and chips.
Among other things, it required the following:
“Flexible plastic hoses must be electrically conductive in order to dissipate static electricity. If this is not the case, the incorporated steel helix must be electrically conductively connected to the machine extraction connection and the permanently installed extraction pipe.”
For practical implementation, reference was made at the time to BGR 132. Today, the requirements for preventing ignition hazards caused by electrostatic charging are specified in particular by TRGS 727.
BGR 739 – Wood dust: handling and safe working practices
The former German Social Accident Insurance rule BGR 739 also contained requirements for the safe handling of wood dust.
Among other things, it stated:
“The pipework must be electrically conductively connected from the machine connection to the main collecting duct.”
For practical implementation, reference was also made to the former BGR 132. When assessing electrostatic ignition hazards today, the current legal and technical regulations, particularly TRGS 727, must be taken into account.
BIA requirements for industrial vacuum cleaners and dust extractors
Requirements for preventing electrostatic charging were also formulated for industrial vacuum cleaners and dust extractors. The former BIA specifications stated, among other things:
“The grounding of conductive accessories must be ensured. All conductive parts of the appliance (including accessories) must be electrostatically grounded …”
The former German Berufsgenossenschaftliches Institut für Arbeitssicherheit (BIA) has since been incorporated into the Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA), the Institute for Occupational Safety and Health of the German Social Accident Insurance. The current regulations and DGUV information must therefore be consulted when assessing specific applications.
ATEX Directive 2014/34/EU
ATEX Directive 2014/34/EU governs the placing on the market of equipment and protective systems intended for use in potentially explosive atmospheres. It has applied since 20 April 2016 and replaced the former Directive 94/9/EC.
The Directive applies in particular to:
- equipment and protective systems intended for use in potentially explosive atmospheres;
- certain safety devices, controlling devices and regulating devices; and
- components intended to be incorporated into such equipment and protective systems.
Within equipment group II, the ATEX Directive distinguishes between three equipment categories with different levels of protection:
- Category 1: very high level of protection
- Category 2: high level of protection
- Category 3: normal level of protection
The equipment and protective measures required depend on the particular application, the potentially explosive atmosphere and the underlying risk assessment.
Potentially explosive atmospheres and zones
Potentially explosive atmospheres can be classified into zones according to the likelihood and duration of the occurrence of a hazardous explosive atmosphere.
For areas containing flammable gases, vapours or mists, a distinction is made between Zones 0, 1 and 2:
- Zone 0: A hazardous explosive atmosphere is present continuously, for long periods or frequently.
- Zone 1: A hazardous explosive atmosphere is likely to occur occasionally during normal operation.
- Zone 2: A hazardous explosive atmosphere is not normally likely to occur during normal operation. If it does occur, it will do so only infrequently and for a short period.
For areas containing combustible dusts, a corresponding distinction is made between Zones 20, 21 and 22:
- Zone 20: A hazardous explosive atmosphere in the form of a cloud of combustible dust is present continuously, for long periods or frequently.
- Zone 21: A hazardous explosive atmosphere in the form of a cloud of combustible dust is likely to occur occasionally during normal operation.
- Zone 22: A hazardous explosive atmosphere in the form of a cloud of combustible dust is not normally likely to occur during normal operation. If it does occur, it will do so only infrequently and for a short period.
Suitable equipment, protective systems and other work equipment must be selected on the basis of the relevant risk assessment.
What is an explosive atmosphere according to ATEX?
For the purposes of ATEX Directive 2014/34/EU, an explosive atmosphere is a mixture with air, under atmospheric conditions, of flammable substances in the form of gases, vapours, mists or dusts in which, after ignition has occurred, combustion spreads to the entire unburned mixture.
Whether an explosive atmosphere can form depends, among other things, on the substances present and the local and operating conditions.
When does ATEX Directive 2014/34/EU apply?
| Analysis | Result | ||
|---|---|---|---|
| Equipment with its own potential source of ignition | Equipment intended for use in or in connection with potentially explosive atmospheres | Equipment in which an intended internal explosive atmosphere is present | Equipment falling within the scope of ATEX Directive 2014/34/EU |
| Yes | Yes | Yes | Yes |
| No | Yes | Yes | No |
| Yes | No | Yes | No |
| Yes | Yes | No | Yes |
| No | No | Yes | No |
| Yes | No | No | No |
| No | Yes | No | No |
| No | No | No | No |
ATEX Directive 2014/34/EU does not automatically apply to every product used in a potentially explosive atmosphere.
It applies in particular to equipment that can cause an explosion due to its own potential sources of ignition, protective systems and certain components, safety devices, controlling devices and regulating devices.
Irrespective of this, possible ignition hazards must be taken into account in the risk assessment when work equipment and connecting devices are used in potentially explosive atmospheres.
When selecting and using hoses, it is therefore crucial to determine whether they can be used safely under the specific operating conditions and which requirements arise from the particular application, the media being conveyed and any potential electrostatic charging.
Application to Norres Baggerman hoses
When selecting hoses for potentially explosive atmospheres, potential electrostatic charging and the resulting ignition hazards must be taken into account.
Depending on the application, conveyed medium, hose construction and operating conditions, different requirements may apply to the electrostatic properties of a hose.
Norres Baggerman offers hose solutions with different electrostatic properties for such applications. Suitable products are identified by the relevant symbols for antistatic or dissipative (AS) or electrically conductive (EC) versions.
Conductive components such as support helices and fittings must be grounded or incorporated into the potential equalisation system in accordance with the requirements applicable to the particular application.
Whether a specific hose is suitable for a particular application must be assessed by taking into account the operating conditions, conveyed medium, installation situation and risk assessment.
TRGS 727 – Avoidance of ignition hazards due to electrostatic charging
TRGS 727 “Avoidance of ignition hazards due to electrostatic charging” specifies the requirements of the German Hazardous Substances Ordinance for preventing ignition hazards caused by electrostatic charging.
It replaces the former TRBS 2153 and is based, among other things, on findings from the former BGR 132.
With regard to the requirements for pipes and hoses, TRGS 727 distinguishes between different applications and operating conditions. Important factors include the properties of the conveyed medium, the wall construction of the hose, the materials used and the likelihood of an explosive atmosphere.
Conductive components such as support helices and fittings must be grounded or incorporated into the potential equalisation system in accordance with the applicable requirements.
Pneumatic conveying of bulk materials
Special requirements apply to the pneumatic conveying of combustible bulk materials.
When combustible bulk materials are pneumatically conveyed using air, it must generally be assumed that fine dust can create an explosive atmosphere inside the pipes and hoses used. At the same time, the conveying process can generate high electrostatic charges.
TRGS 727 therefore imposes specific requirements on the wall construction and electrostatic properties of the pipes and hoses used.
The through-wall resistance or specific resistivity is decisive when characterising the wall material as conductive or dissipative. Characterisation based solely on surface resistance is not permitted for this purpose.
As part of electrostatic testing and assessments carried out in cooperation with an explosion protection specialist body, hoses of different designs were categorised with regard to their use in potentially explosive atmospheres.
The certificate can be found here:
Important notice:
The selection of a suitable hose and the necessary grounding and potential equalisation measures must always take the specific application and operating conditions into account.
The operator of the respective system is responsible for carrying out the risk assessment and defining the necessary protective measures. The information on this page therefore does not replace an application-specific risk assessment.